TI0944
|
SEC: Defatted soybean flour extract
|
TI0918
|
SEC: Polylysine
|
TI0911
|
SEC: Pectin
|
TI0910
|
SEC: Mannan
|
TI0909
|
SEC: Fucoidan
|
TI0908
|
SEC: hyaluronic acid, sodium salt
|
TI0907
|
SEC: kappa- and iota- Carrageenan
|
TI0904
|
SEC: Carboxymethyl cellulose (CMC)
|
TI0901
|
SEC: Poly-gamma-glutamic acid
|
TI0896
|
SEC: Collagenpeptide
|
TI0895
|
SEC: Alpha-lactalbumin, from bovine milk
|
TI0894
|
SEC: Alpha-Casein, from bovine milk
|
TI0893
|
SEC: Alpha-chymotrypsinogen A, from bovine pancreas
|
TI0892
|
SEC: Xthantine oxidase (XOD), from Buttermilk
|
TI0891
|
SEC: Beta - Glucosidase
|
TI0889
|
SEC: Alpha - Amylase
|
TI0887
|
NaCl (sodium chloride) in Ramen Soup
|
TI0886
|
S-allyl-L-cysteine in Garlic Extract
|
TI0885
|
Pantothenic acid in a nutritional supplement
|
TI0879
|
Allicin and diallyl disulfide in Garlic
|
TI0878
|
Alliin and S-allyl-L-cysteine in Garlic
|
TI0862
|
LC-MS: Flavonoids
|
TI0861
|
LC-MS: Flavonoids
|
TI0860
|
LC-MS: Flavonoids
|
TI0825
|
Soybean protein
|
TI0810
|
LC-MS: Low-calorie sweeteners
|
TI0804
|
LC-MS: Method for simultaneous analysis of functional ingredients in rice bran oil
|
TI0736
|
The Intrada Amino Acid column is used to separate amino acids present within soy sauce
|
TI0732
|
The Scherzo SM-C18 and Unison UK-Amino columns successfully separate the small, polar ascorbic acid related compounds in normal phase mode.
|
TI0714
|
The Scherzo SM-C18 column is able to retain a highly polar compound (multiple phosphate groups) better than a standard C18 column.
|
TI0693
|
Unison UK-C18 column can separate out the small, polar molecule components of coffee bean extract due to the lower density of C18 ligands. The column can generate 219 peaks, which shows all of the components of the extract.
|
TI0692
|
Both Unison UK-C18 and Scherzo SW-C18 can separate out components of coffee extracts, but Scherzo SW-C18 can resolve the peaks of caffeine and ferulic acid better.
|
TI0659
|
Farnesene isomers
|
TI0647
|
Simultaneous HPLC/LT-ELSD Analysis of Polyols, Mono-,Di- and Oligosaccarides
|
TI0638
|
Theaflavins
|
TI0611
|
Maltol, Ethyl Maltol
|
TI0550
|
Sucralose by reversed-phase analysis
|
TI0541
|
Sodium Sulfite in Red Wine
|
TI0484
|
Denatonium benzoate
|
TI0483
|
Denatonium benzoate
|
TI0482
|
Food preservatives (normal phase)
|
TI0457
|
Sudan Dyes
|
TI0456
|
Malachite Green and Metabolite
|
TI0438
|
Melamine & related compounds
|
TI0437
|
Melamine & Cyanuric Acid
|
TI0424
|
Anthocyanins
|
TI0403
|
Antioxidants
|
TI0378
|
Sulfamic acid and cyclamic acid can be separated by either reversed phase or normal phase chromatography. Reversed phase gives better peak shape while normal phase gives better run time.
|
TI0376
|
Cadenza HS-C18 successfully separates out small molecules like Estradiol and metabolites from bovine serum. The sample chromatogram looks almost identical to the standard chromatogram.
|
TI0373
|
Unison UK-Amino column separates small molecule low-calorie sweeteners with excellent resolution.
|
TI0361
|
Unison UK-Amino is able to separate inositol (an acidic compound) in normal phase/anion exchange mode. This column recognizes inositol from a mixture containing a variety of components.
|
TI0360
|
Unison UK-Amino column separates out taurine in a drink mixture.
|
TI0356
|
Stevia sweeteners
|
TI0348
|
Organic acids
|
TI0331
|
Fatty acids
|
TI0292
|
Caffeine in the Caffe Latte
|
TI0261
|
EDTA-Chelates
|
TI0246
|
Separation properties for acidic compounds on CL-C18
|
TI0244
|
|
TI0243
|
Vanillin and Guaiacol Derivatives
|
TI0238
|
Stevia sweeteners
|
TI0207
|
500fg of Coenzyme Q10 can be quantitated by utilizing our 3um C8 column and a sensitive LC-MS/MS detector.
|
TI0195
|
Analysis of coenzyme Q10, a dietary supplement used for its antioxidant action, with various columns.
|
TI0194
|
Analysis of hinokitiol, a compound for whose antibacterial and other physiological properties have been observed.
|
TI0191
|
Reverse phase analysis of the highly polar compound betaine, which is quite difficult to retain in normal phase analysis.
|
TI0190
|
Separation of short chain cable fatty acids without modifying the functional group.
|
TI0185
|
Normal phase analysis of the synthetic sweetener saccharine.
|
TI0172
|
Normal phase separation of acrylamide, the presence of which in common foods has caused health concerns.
|
TI0170
|
The polar compound L-Carnitine, analyzed in both normal and reverse phase modes.
|
TI0161
|
Analysis of an antioxidant food additives.
|
TI0151
|
Caproic acid and its methylvaleric acid isomers are separated with high resolution using our 500mm long column.
|
TI0127
|
High-speed separations with Unison UK-C8 150mm column compared with a 5um 250mm column popular on the market.
|
TI0120
|
Analysis of copper chlorophylline, a chlorophyll derived food additive.
|
TI0110
|
Superior separation of US-C18 compared to competitor columns.
|
TI0109
|
Comparative separation of organic acids with various stationary phases of the Unison series.
|
TI0107
|
Comparative retention of the highly polar compound acrylamide in the Unison series using 100% aqueous mobile phase.
|
TI0095
|
Nonaqueous reverse phase analysis of purified fish oil including DHA glyceride.
|
TI0073
|
Gradient analysis of food dyes, including Rose Bengal and erythrosin
|
TI0053
|
Analysis of creatine in chewing gum
|
TI0042
|
High speed separation of low calorie sweeteners.
|
TI0038
|
Cadenza's separation is superior to that of two conventional ODS columns back to back.
|
TI0037
|
Cadenza's separation is superior to that of two conventional ODS columns back to back.
|
TI0036
|
Cadenza's separation is superior to that of two conventional ODS columns back to back.
|
TI0035
|
Cadenza's separation is superior to that of two conventional ODS columns back to back.
|
TI0034
|
High speed separation of benzoic acid and sorbic acid in soy sauce.
|
TI0033
|
Using our Cadenza 3um column, high-speed charge separation of food preservatives is possible.
|
TI0029
|
This polar hydrocarbon can eluate with low use of solvent, in this case methanol.
|
TI0028
|
High-speed separation of the many components of pepper.
|
TI0026
|
Analysis of the components of two types of olive oil, including triglyceride.
|
TI0017
|
Complete separation of cis and trans isomers of oleic acid
|
SP0031
|
Simultaneous analysis of 15 water-soluble vitamins in beverages and dietary supplements with multi-mode ODS column using LC-MS/MS
|
SP0030
|
High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS
|
SP0027
|
Advantage of a New Generation of Evaporative Light-Scattering Detectors: Universality, Higher Sensitivities and Cost-Effectiveness for Multi-Element Analyses in Liquid Chromatography - An Application Review
|
SP0018
|
A high throughput solid phase extraction method for vitamin B3 and related metabolites from pooled human serum using ISOLUTE SCX-3 96 well plates prior to mixed mode LC-MS/MS
|
JA0024
|
Anti-hepatitis C virus compounds obtained from Glycyrrhiza uralensis and other Glycyrrhiza species
|
JA0022
|
Comprehensive analysis of pharmaceutical products using simultaneous mixed-mode (ion-exchange/reversed-phase) and hydrophilic interaction liquid chromatography
|
JA0015
|
Improved production of 2-keto-3-deoxy-d-glycero-galactononulosonic acid (KDN) using FastPrep-CLEAs
|